Evaluating the Effectiveness of Adaptive Shading Systems in Improving the Thermal and Visual Performance of Office Buildings in Hot-Arid Regions: A Critical Comparative Review with an In-Depth Analysis of the Libyan Environmental Context

Authors

  • Maha Abdul Rahman Aqeel Higher Institute of Science and Technology – Tripoli, Libya Author

DOI:

https://doi.org/10.65405/5sh92z17

Keywords:

Adaptive Shading Systems; Kinetic Façades; Office Buildings; Thermal Performance; Visual Comfort; Hot-Arid Climate; Libyan Environment; Energy Efficiency

Abstract

Office buildings in hot and arid climatic regions face increasingly complex environmental and energy-related challenges associated with intense direct solar radiation and rising cooling and air-conditioning loads, alongside the critical need to provide adequate levels of natural daylight that ensure visual comfort and support occupants’ workplace productivity. This study aims to provide an in-depth critical, analytical, and comparative review of the potential of adaptive shading systems (kinetic and dynamic façades) in comparison with conventional static shading systems, while identifying the key factors and conditions governing their environmental and operational effectiveness. The research adopts a descriptive, analytical, and comparative methodology through the critical examination and synthesis of evidence drawn from a purposively selected sample of ten peer-reviewed studies published in international scientific journals between 2013 and 2026.

The analysis is structured around five principal dimensions: temporal responsiveness, thermal performance, daylighting efficiency and glare mitigation, algorithm-based control strategies, and the limitations associated with maintenance requirements and mechanical complexity. Furthermore, the study devotes a comprehensive and extended discussion to the implications and potential applications of these technologies in office buildings within the Libyan context, incorporating a comparative analysis of coastal cities, such as Tripoli and Benghazi, and hot inland and desert regions, including Sabha and Ghadames.

The findings indicate that the ability of adaptive shading systems to move and adjust their configurations provides considerable flexibility in solar control. However, such adaptability does not inherently guarantee energy savings or the complete elimination of visual glare. Actual performance depends on the complex interaction of several factors, including façade orientation, glazing types and performance characteristics, control algorithms, and local environmental challenges, such as dust and sand accumulation, coastal humidity, high maintenance costs, and the availability of qualified technical personnel.

The study concludes that the assumption of the universal superiority of kinetic façades over conventional static shading systems should be reconsidered. Instead, a comprehensive multi-criteria evaluation framework is recommended to balance sustainable environmental performance, occupant comfort, and operational readiness before implementing adaptive shading technologies in office buildings across Libya.

Downloads

Download data is not yet available.

References

1. Al-Masrani, S. M., & Al-Obaidi, K. M. (2019). Dynamic shading systems: A review of design parameters, platforms and evaluation strategies. Automation in Construction, 102, 195–216. https://doi.org/10.1016/j.autcon.2019.01.014

2. Avcı, P., Ekici, B., & Kazanasmaz, Z. T. (2025). A review on adaptive and non-adaptive shading devices for sustainable buildings. Journal of Building Engineering, 100, 111701. https://doi.org/10.1016/j.jobe.2024.111701

3. Bakker, L. G., Hoes-van Oeffelen, E. C. M., Loonen, R. C. G. M., & Hensen, J. L. M. (2014). User satisfaction and interaction with automated dynamic facades: A pilot study. Building and Environment, 78, 44–52. https://doi.org/10.1016/j.buildenv.2014.04.007

4. Barozzi, M., Lienhard, J., Zanelli, A., & Monticelli, C. (2016). The sustainability of adaptive envelopes: Developments of kinetic architecture. Procedia Engineering, 155, 275–284. https://doi.org/10.1016/j.proeng.2016.08.029

5. Building and Environment (2026). Advanced hybrid shading systems and multi-objective optimization for indoor thermal-visual comfort. Special Review Issue on Sustainable Building Envelopes, 114905.

6. Humaidan, O., Almazam, K., Bashir, F. M., Alshayeb, M. J., Al-Tamimi, N., & Dodo, Y. A. (2025). Comprehensive assessment of dynamic shading devices for daylighting and energy management in Saudi Arabian hot-arid buildings. Energy and Buildings, 346, 116180. https://doi.org/10.1016/j.enbuild.2025.116180

7. Krarti, M. (2022). A comparative energy analysis of dynamic external shadings for office buildings. ASME Journal of Engineering for Sustainable Buildings and Cities, 3(2), 021001. https://doi.org/10.1115/1.4054775

8. Loonen, R. C. G. M., Trčka, M., Cóstola, D., & Hensen, J. L. M. (2013). Climate adaptive building shells: State-of-the-art and future challenges. Renewable and Sustainable Energy Reviews, 25, 483–493. https://doi.org/10.1016/j.rser.2013.04.016

9. Nagy, Z., Svetozarevic, B., Jayathissa, P., Begle, M., Hofer, J., Lydon, G., Willmann, A., & Schlueter, A. (2016). The Adaptive Solar Facade: From concept to prototypes. Frontiers of Architectural Research, 5, 143–156. https://doi.org/10.1016/j.foar.2016.03.002

10. Tungnung, K. (2025). Parametric passive design strategy towards sustainable net-zero energy buildings in hot-dry climate zones of India. Solar Energy, 113515. https://doi.org/10.1016/j.solener.2025.113515

Downloads

Published

2026-10-29

How to Cite

Evaluating the Effectiveness of Adaptive Shading Systems in Improving the Thermal and Visual Performance of Office Buildings in Hot-Arid Regions: A Critical Comparative Review with an In-Depth Analysis of the Libyan Environmental Context. (2026). Al-Farooq Journal of Sciences, 2(4), 1248-1261. https://doi.org/10.65405/5sh92z17