Evaluating the HVAC System Design for Operating Rooms in Nalut Central Hospital According to International Standards
DOI:
https://doi.org/10.65405/1qv5xy83الكلمات المفتاحية:
HVAC System, Operating Rooms, Positive Pressure, Air Change Rate, Healthcare-Associated Infection .الملخص
This research aims to evaluate the Heating, Ventilation, and Air Conditioning (HVAC) system in the operating theaters of Nalut Central Hospital and analyze its compliance with approved international standards such as ASHRAE Standard 170 and WHO Guidelines for Surgery. The study adopted a comprehensive analytical approach, combining field visits, technical records review, and direct interviews with staff to assess the system's performance and adherence to modern operating room requirements. The findings revealed that the previously used non-centralized HVAC system had significantly exceeded its recommended operational lifespan. It failed to achieve essential requirements, including positive pressure, standard Air Change Rates (ACH), or precise temperature/humidity control. Currently, the hospital relies on household air conditioners (Split Units) and natural ventilation, which are entirely incompatible with surgical requirements, posing a significant risk of Surgical Site Infections (SSI). The study concluded that the current system is unable to meet standard specifications, necessitating immediate corrective actions, including the installation of a compliant centralized HVAC system.
التنزيلات
المراجع
[1] F. Memarzadeh, "Guidelines for environmental control in hospital operating rooms," National Institutes of Health (NIH), 2009.
[2] Centers for Disease Control and Prevention (CDC), "Guidelines for environmental infection control in health-care facilities," MMWR, vol. 52(RR-10), pp. 1–42, 2003.
[3] ANSI/ASHRAE/ASHE Standard 170, "Ventilation of health care facilities," American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, USA, 2021.
[4] World Health Organization (WHO), "Guidelines for the prevention of surgical site infection," WHO Press, 2016.
[5] W. Whyte, D. Vesley, and R. Hodgson, "Bacterial contamination of air in operating rooms," Journal of Hospital Infection, 2001.
[6] T. T. Chow and X. Y. Yang, "Ventilation performance in operating theatres against airborne infection," Journal of Hospital Infection, 2005.
[7] S. SadriZadeh and A. Aganovic, "Design of operating room ventilation using computational fluid dynamics," PhD thesis, KTH Royal Institute of Technology, Stockholm, Sweden, 2016.
[8] M. Alsved et al., "Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflow," Journal of Hospital Infection, vol. 98, no. 2, pp. 181-190, 2018.
[9] J. A. Wagner, D. G. Greeley, and T. C. Troy, "Airflow in the operating room," United States, 2018.
[10] F. Romano, S. Milani, R. Ricci, and C. M. Joppolo, "Operating theatre ventilation systems and their performance in contamination control," International Journal of Environmental Research and Public Health, vol. 17, no. 19, p. 7275, 2020.
[11] M. Al-Khalaf, A. Ilinca, and M. Y. Hayyani, "CFD investigation of ventilation strategies for contaminant removal in hospital rooms," Designs, vol. 7, no. 1, p. 34, 2023.
[12] BAKA, M. M., & ERYILDIZ, S. (2026). The Developing Public Square Into Eco Square (Case Study Of Martyrs Square, Tripoli) Transforming Martyrs’ Square in Tripoli into an Eco-Square: A Sustainable Framework for Urban Public Space Regeneration. Al-Farooq Journal of Sciences, 2(4), 250-266.